AutoInsider Logo

Citroen C5 air blower not working

2002 Citroen C5 Problem

The Problem:

The Problem

Aircon/climate control fan indicator LCD "lights up" when ignition turned on. After starting, within seconds, the LCD fan only shows fan outlines and fan is off.
air con etc will not work as blower will not come on at all, was working when went into work but not when i returned to car. can anyone suggest a fix/check, I have checked and relaces fuses in glove box and under bonnet.



thankyou

Ref#5610
CarCitroen C5
Year2002
Ownerjorja
Posted03/08/2010


More Citroen and C5 problems


Solution 1

whittingehame | Legend | Since: Oct 2009 | Posts: 443 | Fixes: 9022 | View Garage
Suggested Solution

From another forum re. same fault .


CITROEN C5 AIR CON BLOWER MOTOR?
I HAVE AN 2003 C5 2.2HDI EXCLUSIVE WITH AUTO AIR CON. THE BLOWER WAS WORKING FINE ON AUTO SETTING, THEN SUDDENLY WENT OFF WITHOUT ANY WARNING WHILE STILL DISPLAYING AS ON. IS THIS LIKELY TO BE THE MOTOR OR AN ELECTRONIC ISSUE.


A new control module cured mine. No fan power at all was the fault. Price 58 +Vat.

Phil S
February 2010

99% chance its the fan control module it's located in the heater unit ,to gain access remove the shroud under the steering wheel the fan control module has 2 seperate plugs one with a thick red and black cable the other with a thick red and black cable and 2 thinner cables it is held in in place with 2 hexagon screws the top one is difficult to see without a torch it is very easy to remove, it can only be obtained from main dealers and costs about 58 quid inc vat just changed mine with same symptons and now works perfectly a very common problem on all french cars




Posted on Wednesday 4th of August 2010